    Raised spa losing water with pump off and on

    Do you have a waterfall plus a raised spa? I do and if you do you probably have a check valve in between the two somewhere behind the spa. What i have is a valve to regulate the flow from the spa to the waterfall and vice versa. If it's like mine there will be a check valve at that valve. that...
  2. S

    Minimax 400 heats fine but service light stays on

    I have the same heater and it used to have three lights come on when heating and two after temp is reached. Now it has only two that come on and one when temp is reached. I can live with that. Other than maybe a light being burnt out everything still works! :p
  3. S

    Jandy PDA problem

    OK, So by moving the antenna to a place where it can not be seen by the equipment worked. It was not overheating as i suspected it was. I downloaded the instruction manual and it said the antenna had to be at least 10 feet from a blower and all the equipment is in an enclosed block wall area...
  4. S

    Jandy PDA problem

    Well, Thank you for your response. I did think i allowed time, but, thought maybe I had stumped the panel. That being said I do have enough extra cable to try other areas and hopefully that will solve the problem. I had already moved it twice and it didn't seem to help, but I will try a couple...
  5. S

    Jandy PDA problem

    Wow. nobody else has ever had this problem!!!
  6. S

    Jandy PDA problem

    OK, my first post to this so i hope i'm doing it correctly. I have a Jandy PDA system on the pool that is controlled by the handheld remote. I do not have an aqualink control inside the house, but i can control everything fine with the remote, however, this is the crazy part. When the sun is at...