Recent content by sailor

  1. S

    Hayward pump ...motor problem

    I feel like an idiot not having bypassed the feed wire....I had checked the connections etc and got nowhere ....never dawned on me that the cord itself could have a fault in it
  2. S

    Hayward pump ...motor problem

    It was silent...no buzz, nothing. BUT this afternoon I was about to cut it out of the plumbing to get it in on the bench...and decided that before I did that I would try one last thing.. I took the tail off another pump someone had given me as a loaner...which was useless since it was...
  3. S

    Hayward pump ...motor problem

    I pulled the capacitor out of this and brought to a local shop this morning to have tested....it's fine. Anyone come up with any ideas? If I bring them the motor it looks like 10 days to 2 weeks.....
  4. S

    Hayward pump ...motor problem

    The Hayward model number for the pump is SP2605X7, the motor is an AO Smith C48J2N131B1 and I think the new/current Century number is UST1072
  5. S

    Hayward pump ...motor problem

    The first couple times I started it today it came on but only for a moment..barely a second. Now there is nothing. When I open the strainer I can get a finger into the impeller and it does not feel clogged and it is spinning freely. I've been over the connections - took them apart and cleaned...
  6. S

    Hayward pump ...motor problem

    I've got a Hayward sand filter and pump with the motor that was supplied with it. Last night the pump was running fine when I shut it down about 10- ran late since I had shocked the chlorine. This morning when I went out to turn it on the motor came on momentarily then stopped. Turned it...