Recent content by rbackous

  1. R

    Cell or current resistor (limiter)

    But when the mineral counts were up, it was generating chlorine just fine. Is there a way I can override the reading? I'm in a northern climate and only have about a month of good pool time left. If I could limp along another month and deal with it next year I'd be happy.
  2. R

    Cell or current resistor (limiter)

    I meant to post an update about a week ago that you guys were absolutely right. I've brought my CYA up to 40 and now my chlorine levels are at 8.1. Everything seemed to be working perfectly for the last couple of weeks. Now all of the sudden, my mineral levels *seem* to have dropped suddenly...
  3. R

    Cell or current resistor (limiter)

    See my responses above. I got these readings from the local pool store I ran for 2 full weeks and FC/TC went from 1.1 to 1.4. Also I read the MS-10 values and posted below: 1. Temp - 84 2. Cell voltage - 25.5 3. Cell current - 5.46 4. output % - 100P 5. salinity - -2500 6 product name -...
  4. R

    Cell or current resistor (limiter)

    Hmmm, I have my water tested regularly by our local pool store and most of the reports read either a CYA of "0" or "Not Tested". If CYA is so important, why are they not testing for it or saying something if "0"? I did find a report with 30 and another with 60, but both of those were last...
  5. R

    Cell or current resistor (limiter)

    I've been reading a lot of posts about cells going bad and current resistors going bad. My question is, what are the symptoms of each? My MS-10 with T-cell 15 stopped generating chlorine. However, how do I tell which of the two might be causing the problem? My voltage is around 25.5 and my...