  1. N

    IC60 flow light turns red after 10 to 50 minutes

    Problem appears to be solved. My PB added 12 inches of straight pvc in front of (leading into) the IC60 2 days ago and I have had a continuous green flow light on low pump speed since then. Keeping my fingers crossed but it appears that turbulent flow was the problem. Thanks to all for their...
  2. N

    IC60 flow light turns red after 10 to 50 minutes

    According to Pentair's literature, both the IC40 and IC 60 require the same flow rate, 25 gal/min, to activate the chlorinator. It still doesn't make sense to me that the IC60 will make chlorine on low pump speed with a green flow light for up to 49 minutes (always more than 8 minutes) before...
  3. N

    IC60 flow light turns red after 10 to 50 minutes

    To his credit, my PB finally changed out my IC40, which based on prior post a couple of weeks ago, was probably undersized or malfunctioning (I could never get any chlorine reading at all unless I left it on 100% for several days in a row). At my request (and based on some feedback from this...
  4. N

    Zero chlorine in pool with Intellichlor IC-40, algae growing

    Re: Zero chlorine in pool with Intellichlor IC-40, algae gro Just a quick response to your questions- I will put info in signature line later today. Plenty of salt was added by pool service guy(20 forty pound bags) and I added three more to bring salt level to 3200-3450 (proper range). It has...
  5. N

    Zero chlorine in pool with Intellichlor IC-40, algae growing

    I had my Ig pool completed 4 weeks ago. We started using it 7/29. I have never had any readable free chlorine in the pool by dipstick or color change test with the unit set at 50% on low speed or high speed, running it at least 12 hours/day, 7am to 7pm. I am using the TF-100 kit. My pool is...