Recent content by Nemesis

  1. N

    MasterTemp - Both Spa On and Pool On Lights Blinking Rapidly

    Re: MasterTemp - Both Spa On and Pool On Lights Blinking Rap Problem resolved. After working with the Pentair Tech we were able to narrow it down to the circuit board being faulty. I have an identical heater which I installed on our Spa at the same time. Swapping circuit boards confirmed the...
  2. N

    MasterTemp - Both Spa On and Pool On Lights Blinking Rapidly

    Re: MasterTemp - Both Spa On and Pool On Lights Blinking Rap In order to try to resolve this issue as quickly as possible I had also posted the question on Pentair's PoolFYI forum. To keep this thread up to date I will copy and paste the posts from there. Please feel free to provide any...
  3. membrane.jpg

    membrane.jpg

  4. N

    MasterTemp - Both Spa On and Pool On Lights Blinking Rapidly

    Re: MasterTemp - Both Spa On and Pool On Lights Blinking Rap Thank you for the quick reply! I just verified again and no, there are no other LEDs lit on the board. The only lights that come on are the Pool On and Spa On lights which blink rapidly.
  5. N

    MasterTemp - Both Spa On and Pool On Lights Blinking Rapidly

    I have a MasterTemp 250 propane heater which I installed about a month ago. The heater has ran for no more than ten hours to date. It is installed indoors to heat an indoor pool and is not exposed to the elements. The heater was turned off for the last week. I went to turn the heater on...
  6. N

    MasterTemp 250 Indoor Venting Question

    Makes sense. Thank you for the detailed reply! I will start getting the parts on order and redo it.
  7. N

    MasterTemp 250 Indoor Venting Question

    Racket: Is there a reason why the Selkirk can not be utilized? I am just asking because our local Big Box stores sell it for use as exhaust vent on gas fired appliances including hot water heaters, gas fireplaces and the such within a home. The existing venting was installed by a professional...
  8. N

    MasterTemp 250 Indoor Venting Question

    I am in the process of replacing two MiniMax Heaters with MasterTemp 250s on an indoor pool and hot tub configuration. They have completely reconfigured the vent (as well as everything else) on these 250s. I would like to utilize the current venting which runs outside of the building. The...
  9. N

    Inground/Indoor Pool Pump and Heater Replacement Suggestions

    Re: Inground/Indoor Pool Pump and Heater Replacement Suggest More pics: [attachment=2:uvlnmbz3]100_0649.jpg[/attachment:uvlnmbz3] [attachment=1:uvlnmbz3]100_0844.jpg[/attachment:uvlnmbz3] [attachment=0:uvlnmbz3]100_0839.jpg[/attachment:uvlnmbz3]
  10. 100_0839.jpg

    100_0839.jpg

  11. 100_0844.jpg

    100_0844.jpg

  12. 100_0649.jpg

    100_0649.jpg

  13. N

    Inground/Indoor Pool Pump and Heater Replacement Suggestions

    Re: Inground/Indoor Pool Pump and Heater Replacement Suggest Linen, thank you for the reply! We do not actually close on the house until next week. I will get a complete set of test results and post them after I have access to the pool. I have attached a few pictures to help. I believe they...
  14. 100_0648.jpg

    100_0648.jpg

  15. 100_0638.jpg

    100_0638.jpg