Recent content by luna

  1. L

    low salt readings

    Actually, I had ordered the T-3 cell, after consulting with the supplier, who indicated it was the correct cell for my size pool. Your recommendation seems sound to me, and I will probably follow it next time. Thanks.
  2. L

    low salt readings

    Thanks for the replies. I fixed the problem. As is often the case, it was partly "operator error", but mostly T-cell manufacturer error. The instructions that came with the replacement T-cell stated the SWG should read T-15, which it did. However the new T-cell was actually a T-3. After the...
  3. L

    low salt readings

    Hello. I'm new to the forum and am looking to get some help with the latest problem with my SWG. I live in Orlando, FL and have a 12,000 gal in ground pool with an Aquarite SWG. The last two times I had the water professionally tested, everything checked out fine. The pool chemistry was all...