  1. lf-pool

    Replace Intermatic Control Panel - Electrical Questions

    The markings on the wiring is not legible. It could pass for a #6 or and #8. However, I took a part the panel and measured the thickness. I'm pretty sure it's #6 THWN. On a spectate note, I added in a second timer to run my SWG. I'll be sharing that project on a future post.
  2. lf-pool

    Replace Intermatic Control Panel - Electrical Questions

    JZA1736, thank you for the response. You bring up a great point on the #8 THWN. It was a detail i glossed over since i didn't touch the 60A main circuit breaker feed into the subpanel nor the wiring. I went back and remeasured the thickness and it looks more like #6 THWN, which is rated at 65...
  3. IMG_4389.jpg

    IMG_4389.jpg

  4. lf-pool

    Replace Intermatic Control Panel - Electrical Questions

    I didn't receive any comments, but I wanted to share that I completed the Intermatic timer control panel replacement! A1: Circuit Breakers configurations - 60 Amp feed from Main power panel (8 AWG). This control panel is broken up into 2 buses - Phase A and Phase B. I decided to reorder my...
  5. IMG_4378.jpg

    IMG_4378.jpg

  6. lf-pool

    Replace Intermatic Control Panel - Electrical Questions

    Below are some pics. Clearly you can see I need to replace the panel! Q2: I'm thinking of using butt connectors, wire nuts, or I may be able to drop the control box down a couple inches. I have to believe rain/sprinklers caused all this damage. I have since removed the sprinklers, but we...
  7. IMG_4287.jpg

    IMG_4287.jpg

  8. IMG_4288.jpg

    IMG_4288.jpg

  9. lf-pool

    Replace Intermatic Control Panel - Electrical Questions

    Hello, I'm looking to replace my Intermatic Control panel with a slightly different model Intermatic control panel. I chose to use a single timer since I removed a booster pump. I want to make several changes in the process and created a couple of diagrams to help illustrate. If the...
  10. Proposed.jpg

    Proposed.jpg

  11. Existing.jpg

    Existing.jpg

  12. lf-pool

    Grout - how long to wait before filling water

    Hello, I have replaced all my waterline tile in my spa. I have the 1x1" glass mosaic tiles mounted with thinset and ready to grout. I wanted to take a poll and see how long you would wait after grouting before filling the so with water.
  13. lf-pool

    Raised Spa/Jacuzzi - cracked tile line repair

    Thank you ... I appreciate your response.
  14. lf-pool

    Raised Spa/Jacuzzi - cracked tile line repair

    Thank you for the reply pooldv. Yes, I had the pool guys add in an expansion joint around the perimeter of our pool and spa. For waterline tile, I have thinset and grout from the pool store. If concrete is used and knowing hat its porous, would the grout or thinset prevent water for...
  15. IMG_3536.jpg

    IMG_3536.jpg