Recent content by Knetsel

  1. K

    Data regarding protection from UV by CyA

    Hello, To mas85 : did you measure pH as well as Cl and CyA ?
  2. K

    Data regarding protection from UV by CyA

    Thank you very much JoyfulNoise for this paper. I already had a copy of it and found it most interesting especially for what concerns disinfection by UV-C (It mainly deals with 254 nm UV when sunlight UV reaching earth have a wave length over ~ 280 nm). However there are some considerations...
  3. K

    Data regarding protection from UV by CyA

    Thank you very much for all this information. Re-readng the reports concerning CyA and OCl photolysis to which I have access, the best (?) data I have been able to find are those from Nelson (Monsanto report 6862) and Canelli (1974) which have been reproduced and used under graphical format by...
  4. K

    Data regarding protection from UV by CyA

    Hello, Still interested in the theory and consequences of chlorine protection from UV by CyA, I'm looking for data published in scientific or technical papers relating to measurements concerning this protection. I have seen, here and there, mentions of such papers as well as curves "based" on...
  5. K

    Help with Biofilms

    do you have biofilm i,n the plumbing ? How can one detect this ? will plumbing develop biofilm if HOCl is high enough ?
  6. K

    I don't understand the need to use CyA

    Hello Thank you for your answers which helped me understand the subject a bit better. These answers, however, raise a few other questions to me : 1 - You say that 0.05 ppm of HClO is enough to control pathogen and algae an overdosing of chlorine would make the water harsh to eyes, skin, and...
  7. K

    I don't understand the need to use CyA

    Hello, Thank you for your answers which helped me understand the situation a bit better. These answers, however, raise a few other questions to me : 1 - you s
  8. K

    I don't understand the need to use CyA

    Hello, There must certainly be a few (many ?) places here where this is discussed in depth. Could you please show me the way to the most relevant ones ? Thank you in advance. Nota : pool in France, pH and chlorine controlled via peristaltic pumps, pH and ORP probes, sulfuric acid (PVC liner)...
  9. K

    CyA and TA measurement

    Hello, This test confirms, at least to myself, that alkalinity measured via my photometer is coherent with the classical drop count test. I will try to make a similar test with much more stab in the water so as to have a higher contribution for Cya Alkalinity. Thank you again for your...
  10. K

    CyA and TA measurement

    I compared results of total alkalinity tests made with : a) my Lovibond 620 and alkalinity-m tablets and b) a Hanna total HI3811 alkalinity kit with drops of acid and bromophenol blue as indicator. Both give coherent results with or without ~ 20 ppm Cya in pool water. These tests were performed...
  11. K

    CyA and TA measurement

    OK with you regarding the poor quality of test strips measurements. No doubts that a test made with drops is the best one. My photometer is a Lovibond 620 and I think that one can trust the measures made with it; the question is just "does it takes CyA alkalinity into account" ? May be the best...
  12. K

    CyA and TA measurement

    Hello, Thank you for your answers. I know how to get Carbonate alkalinity from TA in the presence of CyA by using the pH dependent correction factor or via pool math app. As I'm using a photometer, I would like to know if the value for TA obtained with it is the same as the one obtained with...
  13. K

    CyA and TA measurement

    Hello, A question regarding the correction factor to be applied at Total Alkalinity measurement in order to get Carbonate Alkalinity : does this correction factor applies whatever the measurement type for TA ? Said otherwise, do we get (approximately) the same results for TA whether we use a...
  14. K

    Actual SWCG chlorine rate compared to theory

    I'm just discovering the existence of bipolar electrodes ad will try to dig a bit more into the subject. Thank you very much JamesW.
  15. K

    Actual SWCG chlorine rate compared to theory

    I'm just discovering the existence of bipolar electrodes ad will try to dig a bit more into the subject. Thank you very much JamesW.