Recent content by jsbatch

  1. J

    Paramount Floor Cleaner 6-Port Water Valve - Rebuildable?

    OK. Thanks for the info. After much research I cannot find any source that sells the Paramount Water Valve parts. It appears that one must buy the complete Paramount Water Valve to cure automatic floor cleaning problems. Bummer!
  2. J

    Paramount Floor Cleaner 6-Port Water Valve - Rebuildable?

    I have a Paramount PCC2000 floor cleaning system installed in my Paddock IGP as originally built in 1997. I'm not the original homeowner but I am the second homeowner. So, the Paddock 'lifetime' warranty expired with the sale of the home to me. Boo! in the past six years I've had to replace the...
  3. J

    Dual Intermatic P1353ME Timer Installation - Wiring Questions

    Thanks for the quick input! Yes, more wiring diagram study and thought tonight produced a wiring approach that (I think?) will feed 240V from each dedicated pump circuit breaker to each of the three switched circuits of one P1353ME timer. I can supply 120V line power to both timers (the P1353ME...
  4. J

    Dual Intermatic P1353ME Timer Installation - Wiring Questions

    I plan to upgrade my existing pool 'automation' system by replacing two existing Intermatic T104 240V mechanical timers that now control ON/OFF events for two Pentair WhisperFlo WP-4 single-speed 240V pumps (filter & floor cleaner) with two new Intermatic P1353ME digital timers. My desire in...
  5. J

    replacing two mech timers with a digital-- need wiring advic

    Re: replacing two mech timers with a digital-- need wiring a I have the identical situation as you started with when you replaced the dual Intermatic T104 mechanical timers with the Intermatic P1353ME timer. Only difference in my situation is that I am using two P1353ME timers - one timer to...
  6. J

    Pentair WhisperFlo - Repair cracked volute?

    Thanks for the tip! I found some interesting recommendations for pump volute crack repair on other pool care forums that suggest using high PSI strength epoxy putty to seal the crack - e.g. Rectorseal EP-200 - allow the epoxy putty to cure 24 hours, then liberally apply 3M Marine Adhesive...
  7. J

    Pentair WhisperFlo - Repair cracked volute?

    I have an older Pentair WhisperFlo 1 HP WF-4 pump that operates a Paramount PCC2000 in-floor cleaning system. The pump volute (pump wet end body) has 3 inch long crack that runs through seal plate sealing face (under o-ring) causing significant water leak during pump run. Crack is slightly...