  1. J

    Meyco vs Loop Loc anchor spacing

    I'm looking to replace an old Loop loc cover with a Meycolite mesh cover. Those seem to be the only brands with a 14 x 32 option. Is the anchor spacing the same between the two? I would prefer to reuse the old holes at least.
  2. J

    Gelcoat crack in fiberglass above water

    This has been here for at least the 10 years I have owned the pool, so I suspect it was original subsidence. If I poke at it, it seems shallow, so I'm going on the assumption it's gelcoat only Since I'm going to close up soon, I would like to take care of it with some polyester resin. What is...
  3. 20210906_195254.jpg

    20210906_195254.jpg

  4. J

    Clean and clear RP 200 Suction Relief Valve

    I haven't installed it yet. I can't seem to find a good picture of what it's supposed to look like. I'm guessing that there is a particular orifice size it's supposed to have? I bought it online, so I'm really trying to avoid the hassle of sending it back. I suppose I can try and see if the...
  5. J

    Clean and clear RP 200 Suction Relief Valve

    I just bought a new clean and clear rp 200 filter. I was taking it out of the box and noticed a small, fingernail size piece near the suction relief valve. It's not exactly clear how it would fit back on to it, so I'm not sure if this is something sort of injection molding scud or something...
  6. 20210416_075340.jpg

    20210416_075340.jpg

  7. J

    Loose or corroded intellichlor to motherboard connector

    I noticed the intellichlor was out the other day. I unplugged, then plugged it back into the control board, and it worked for another day Now it seens to only work when I hold it in. There is corrosion only on the DC pin. No water seems to be leaking anywhere. If it is just the harness, that...
  8. 20200908_131122.jpg

    20200908_131122.jpg

  9. 20200908_131113.jpg

    20200908_131113.jpg

  10. J

    Copper Green?

    Pool was Initially clear before memorial day, but the salt was borderline low, and the swg went off for 2 days for low salt before I noticed. I added more salt and shocked since it turned cloudy. The next day, this persistent green appeared. The water is as clear as it can be. There is hardly...
  11. 20200602_204125.jpg

    20200602_204125.jpg

  12. J

    No lights on IC-40. Led D1?

    I'm case anyone pulls up this thread in the future, the problem was the cell, not the board. New cell is working just fine
  13. J

    No lights on IC-40. Led D1?

    I did some quick math. The cell is from 2012. I'm probably at least at 8,000 hours, if not 10. So I'm rolling the dice and buying a new cell. Let's see if this works
  14. J

    No lights on IC-40. Led D1?

    I'm geting about 30 vac into the board. No plate shorts either. I found this old thread. Looks like someone else for 27 VDC and no lights. Must be a specific failure mode. Pentair Intellichlor IC40 Chlorinator--Lights Are Not On
  15. J

    No lights on IC-40. Led D1?

    AC is good. DC 27 volts, but should be 39 according to the board. D1 only lights up when the harness is plugged in. Maybe the board is starting to go?