Recent content by jen140

  1. J

    Need Magnasweep repair in Fort Lauderdale area....

    yes, but no help....
  2. J

    Need Magnasweep repair in Fort Lauderdale area....

    A&A sent a new valve housing assy, but I need to find someone who services these things to put it on..... The 'old' one (12 yrs) developed a leak. The builder was going to change it out, but he hasn't had the time when it was not raining. The company that helps with our AutoPilot system does...
  3. J

    AutoPilot Digital... help please

    Hey Josh.... You were totally right with your diagnosis...that the capacitors were bad. We were referred to our area AutoPilot guy...and yesterday he replaced the DIG-220 unit and the 'newly replaced' power cord (which was bad also). Interesting thing...the capacitors had opened a bit more in...
  4. J

    AutoPilot Digital... help please

    Thanks so much... if I knew now to PM Sean ...I sure would!! Apparently from further testing we may need to replace the whole 'box'.... comments?? It seems that at least three capacitors appear to be bad...so cheapest way with guarantee is to replace the control unit.....(not really cheapest...
  5. J

    AutoPilot Digital... help please

    Added 3 bags of shock for salt pool, 1 gal stabilizer and 8 lbs of calcium hardness...pool is 11 years old.... changed the cable back to the old one, no difference, so put the new one back on... readings still 22V 5a.
  6. J

    AutoPilot Digital... help please

    Added 3 bags of shock for Salt pools and 1 Gal of liquid stabilizer, still need to add 8.9 lbs of calcium hardness... We tried reversing the cell cable (it has 3 holes the RC-42 only uses two... we may try to re-attach the old cable?? It is a Pebble Tec standard size pool with a self...
  7. J

    AutoPilot Digital... help please

    We replaced the cell (SC-48 with the RC-42) and put on a new cord. The tri-sensor cord remains and seems to be working ok. Since replacing the cell, we get 'warnings' ...clean/check cell and sometimes 'low amps'... The test was done when in boost mode. The salt levels are 3200 ppm, the...