Recent content by howard375

  1. H

    dimensions for GLX-Cell-Pipe

    Here are two pictures that show the T-15 cell and valve. I just found out from Inyo pools that the Hayward Glx-Cell-Pipe uses a standard 2 inch pvc pipe.
  2. IMG_0241.jpg

    IMG_0241.jpg

  3. IMG_0240.jpg

    IMG_0240.jpg

  4. H

    dimensions for GLX-Cell-Pipe

    The three way valve looks like it has a threaded fitting that is glued in. Why don't I take a picture of the valve and send it tomorrow. thanks
  5. H

    dimensions for GLX-Cell-Pipe

    I am replacing my Hayward T Cell -15 with a Pool Pilot Nano +and need to redo the plumbing. Unfortunately the union for the T cell is right next to the 3 way valve and I can't find a fitting to attach to the Hayward union, non standard threads. I was hoping to buy a GLX-CELL-Pipe and cut the...
  6. H

    Replace Aqua Logic AQL-PS-8 SWG

    I did replace the K1 relay about 3 years ago, and the board has been working fine till now. But your point may still be valid. Thanks for the advice, I wish I could find out what the failure rates are for Hayward and pentair units and the decision would be easy.
  7. H

    Replace Aqua Logic AQL-PS-8 SWG

    I have an old (10 year) Aqua Logic AQL-PS-8 control system. I have repaired the SWG section of the main circuit board three times and I am starting to have trouble again, the current to the T-15 starts off at 6 amps and over time 50 min the current will drop to approx 3 amps. The T-15 cell is...