Recent content by gtapoolguy

  1. G

    Salt cell showing 0 instant salt

    So I went to the main board, reran the config while the cell was unplugged and reset stats too. After starting up, plugged in the cell. Lo and behold, readings are fine and cell is working (still low salt as expected). Not sure if it's the resetting that did it or the fact that the cell had to...
  2. G

    Salt cell showing 0 instant salt

    Average is showing 3200ppm but that's from last year, cell hasn't quite run the full 24 hrs yet to update. Maybe that's the issue that I need to wait 24 hrs? Don't see any alarms going off either on omnilogic,
  3. G

    Salt cell showing 0 instant salt

    Thanks for the quick replies! I have Hayward omnilogic which doesn't have low salt light, However in diagnostics the instant salt reading is 0. My guess is the actual number is prob around 2000ppm based on last year's number and what I drained and refilled. Will get it checked by the pool...
  4. G

    Salt cell showing 0 instant salt

    I have a Hayward T cell 15 with omnilogic controller. The equipment is from last year. I opened my pool yesterday (aboit 20 hrs ago) and started warming the water. At 66F (12 hrs into heating) I turned on the chlorinator to 100% with heater and pump running. It's about 8 hrs later now, the...
  5. G

    pipe size question

    unfortunately for my setup the salt cell and heater requires at least 30-35gpm to operate... i find for my system the lowest RPMs that works out to is around 1600, any lower and no heat/salt cell.
  6. G

    pipe size question

    higher flow rates when i run 3 sheer descents (3 ft each)... otherwise doesnt work. usually have the pump running at 1700 rpm though, avging around 40 gpm as yours.
  7. G

    pipe size question

    i got a new pool built this summer. all pipes are 2" around equipment/returns except for one 2 ft section between the salt cell and valve actuator which is a flex 1.5" pipe (was put in as a temporary measure but now thinking of leaving it in place). is this going to be an issue longer term as...
  8. G

    Piping / flow questions

    thanks bmoreswim, i was just coming over to ask that same question... jasonlion, will a 2nd skimmer alleviate some of the flow concerns (but keeping all piping at 2")? so now 2x2" pipes coming from skimmer, 4x1.5" returns and 1x2" pipe for sheer 3x3ft sheers?
  9. G

    Piping / flow questions

    the runs are approx 80' long. would it be beneficial to upgrade the sheer descent and skimmer pipes to 2.5 or even 3" pipes? is there any downside to doing that (assuming all return pipes stay at 1.5")? using ecostar variable speed pump, so should be able to dial the power as needed
  10. G

    Piping / flow questions

    Thanks for the quick response. Based on some of the specs I've seen its roughly 1gpm per inch of sheer descent, hence the 108 number. Now I'm thinking of just switching to a single 6ft sheer descent (72 gpm). Would the rest of the plumbing be sufficient with that or should I still look to...
  11. G

    Piping / flow questions

    Getting a 20K pool installed. 36x18 (depths are 3.5 to 7 ft) Have some questions on piping and flow: Current proposed setup with Hayward EcoStar pump: Input: - 1 skimmer, 2" return pipe (no main drains) Output (2" pipe out of pump, split to returns and sheer descent): - 4 returns (1.5"...
  12. G

    Pool dimensions (sizes, depths, steps)

    We are building a pool this summer, would appreciate any feedback on sizes: Rectangle pool size 18x36 (this is set, can potentially change to 18x38) Depth 3.5' to 8' Steps (vinyl over steel): 12" risers, 18' width (across entire side), not sure on length Questions and opinions: What is the...
  13. G

    Hayward's New OmniLogic

    any update on availability/pricing? i'm getting my pool end of june and hoping this is available by then.
  14. G

    Spill-Over spa with automatic cover

    It's a safety cover so can't imagine a hole in it for spillover. Can the pool and spa both circate with the spillover turned off?
  15. G

    Spill-Over spa with automatic cover

    New to pools, have a few questions regarding spill-over spas used in conjunction with an automatic safety cover. - Can the spa AND the pool recycle water while the automatic safety cover is on? I plan on having the safety cover on the pool when it is not in use so will be turning off the...