Recent content by enigmafa

  1. E

    3" Pluming Suction Line Good or Overkill?

    Most builders are going the rout of smaller pumps with larger plumbing 3" however seems to be a little overkill. However a 1 HP or 1 1/2 HP pump should be plenty to turn you pool over (depending on filter, # of jets, and other water features).
  2. E

    AutoPilot DIG-220 intermittently reads 0ppm salt

    We have been having this problem with a dozen or so of our units and Autopilot, rather unmotivated might I add, just sent us a case of their new tri-sensors w/ cord pre installed. They must have had a bad run, this seems to be fixing the problems. Is your cord detachable at the tri-sensor?
  3. E

    SWG - Tiny Cloudy Bubbles coming from jets

    I've worked on pools for 10 years now. I've worked on and installed hundreds if not thousands of SWG, and only just saw my second instance of this problem yesterday. The customer had damaged their pump and had a pretty bad air leak, and was also complaining about cloudiness when the pump was...