    Polaris motor cleaner overheating and shutting down

    The motor is wired for 230. All connector ends have been replaced and checked as well as the wiring. I will check the inside of the impeller housing for an obstruction.
  2. D

    Polaris motor cleaner overheating and shutting down

    This was the 3rd time I replaced the motor. The original impeller was damaged when I replaced it. It was approx. 7 years old.
  3. D

    Polaris motor cleaner overheating and shutting down

    Do you have any suggestions as to what would cause the overload, as I have replaced the breaker, wiring, and control switch.
  4. D

    Polaris motor cleaner overheating and shutting down

    This is the 3rd motor (all new). When the unit is running, the Polaris unit in the pool works normally.
  5. D

    Polaris motor cleaner overheating and shutting down

    I'm having problems with my Polaris cleaner pump running for a few minutes and then shutting off. I have replaced the motor, breaker, switch and wiring. I have had an electrician check the voltage. The motor is rate 6.4/12.8 amps and is pulling 8.7 amps. After motor cools off it will...