Recent content by CPSScott

  1. C

    DR,LF,HH and HL codes very frustrating

    Sounds like the programming is configured for a circulation pump. Verify the dip switches are in the correct positions for the equipment you have.
  2. C

    Hot springs spa- ace salt water system help

    How old exactly is the ace cell? Sounds like the cell is bad just from your description.
  3. C

    Leak repair - DC area?

    It probably would not be noticeable as the water will run down the backside of the spa shell. Use a paper towel or rag and wipe it on the bottom of the light lens from inside the equipment area.
  4. C

    Leak repair - DC area?

    One problem area to check on the older models is the light lens. In the equipment area, remove the black LED light housing which is located behind the IQ2020 control box. If it is a slow leak and it seems to come from underneath, a leak coming from the lens will follow the contour of the shell...
  5. C

    Leak repair - DC area?

    When did you purchase the spa? There are a couple of places to look, but a model year or serial number would be helpful first. Thanks
  6. C

    Anyone have any ideas of how to get Wasps out of my control panel?

    I use this in the field when I encounter a nest. It works very well. http://www.amazon.com/gp/aw/d/B001CTS1I6?cache=68937da12748017ce3e50f8c42409bb1&pi=SY200_QL40&qid=1412213571&sr=8-1#ref=mp_s_a_1_1
  7. C

    FLO Error

    That would be the jet pump for the therapy jets. It works independently of the circulation system.
  8. C

    FLO Error

    That is the circulation pump which pumps water through the heater and will close the flow switch if working properly. Sounds like your pump had pumped its last days.
  9. C

    Possible to remove a blower from system?

    Most manufacturers install a check valve after the blower. There is no need to remove it unless you really want to.
  10. C

    Need help with air controlled panel

    There should be a thermowell for the probe to sit in, or it may attach to the heater in some way. The thermowells are typically located in a 90° elbow...
  11. C

    POOL BUILDER IN NASHVILLE AREA

    We are located in Knoxville and have built pools all over east TN, including KY and one in VA. If you are interested, pm me and I will give you some contact info.
  12. C

    ACE Salt Water sanitizing system and borates?

    Check to see if the ozonator is still plugged into the circuit board. It should be disconnect unless you have a high bather load.
  13. C

    No Bubbles

    Check for kinks/blockage of the ozone tubing. The check valve can also fail completely sealing itself shut. The ozone injector can clog as well.
  14. C

    My Clearcoat is Peeling!

    Can you post a picture?
  15. C

    Hot Spring Vanguard - Ceramic Tri-X Falling Apart???

    I would stick with the standard filters. Although, the Tri-X are supposed to filter better. Kind of like a sand filter, when they get dirty they filter better.