Recent content by Choneykuhn

  1. Choneykuhn

    TA seems stuck

    I don’t leave aeration on - only when it is time to raise pH. I also wait until ph gets to like 7.8 - turn off aeration - put acid until it tests ~7.0 - then start progress over. I will try your way. Mayb the quicker cycles is what I am missing. According to TFP borates help with pH jump and...
  2. Choneykuhn

    TA seems stuck

    TY. Is chlorine best at 7.5% of CYA? I have read 5% as well.
  3. Choneykuhn

    TA seems stuck

    My water of origin is naturally high in TA. I am currently trying to lower my TA to ~80 so I can add borates. I have this issue often. Once I get to about 120 it just doesn’t want to move anymore. I added borates last year with TA of 120 because I couldn’t get it down more. Absolutely love the...
  4. Choneykuhn

    Water gallons in my pool.

    When I ask Google to calculated gallons for an 18’ x 56” AG pool does it take in to consideration it is only filled to ~ 50-52” or is it calculating to a full 56”?
  5. Choneykuhn

    Salt 4800. 300 over max. Concerned?

    I use a Taylor kit to test. My iChlor 15 is not indicating high salt. It is reading 4250. My salt is good light is green. It is indicating it is producing chlorine (the icon is circling). Cell light is green. Flow light is green. I do not rely on anything but my Taylor test kit for levels. I...
  6. Choneykuhn

    Salt 4800. 300 over max. Concerned?

    I am unsure what happened but it is irrelevant at this point salt is 300 over max can I use the next month of top offs to get it down? I just got my TA down and added borates levels are great except for the salt
  7. IMG_2171.png

    IMG_2171.png

  8. Choneykuhn

    Borates at 80 - is it a concern?

    We have no pets. And the buffering effect is what I need. I was concerned about my equipment and the comfort/safety level of the water when we swim. From my reading I thought I was okay but always need reassurance when it comes to the equipment. An investment well worth the enjoyment but an...
  9. Choneykuhn

    Borates at 80 - is it a concern?

    48 hours ago I weighed all the Borax. I measured the acid and according to a strip my borates wound up at 80 rather than 50. Is this a concern? I am doing a TA adjustment to get TA a little lower. I am using MA down to 7.0 and the fountain to bring it up. I did borates because I had terrible...
  10. 8180DAFF-4AA5-45DD-B834-0464D91904EB.png

    8180DAFF-4AA5-45DD-B834-0464D91904EB.png

  11. Choneykuhn

    Can running pump too much change water chemistry?

    I have been at 15ppm fc for about a week (been trying to get it down from over 30 for about 3 weeks) TA is currently 130. Have been working it down from 220. Current pH 7.6. Constantly wants to creep up. Not running my salt cell. It has been rainy cloudy and very cool for the last 30 days. It...
  12. Choneykuhn

    Hi

    I did some Pool School today - our pump basket (i believe that is the correct term) does have some bubbles at the very top of the clear lid. Am I reading correctly that there should be NO bubbles? BTW - I appreciate your patience and answers - pool water is coming around nicely.
  13. Choneykuhn

    Hi

    We are not swimming. Too cold. Still mostly cloudy. Very cool breezes and about 70 degrees outside. My chlorine is down to 12ppm. Is it slow burning off because of the cool weather and no swimmers? It came down 1ppm in 24 hours.
  14. Choneykuhn

    Hi

    Thank you.
  15. Choneykuhn

    Hi

    Do I need an actual Taylor salinity test or can I use the reading on my iChlor15?