Recent content by cchin

  1. C

    A few questions paramount in floor, intelliflo 2, de filter, cracks in waterfall....

    I'll give it a try when I have time. Pretty cool stuff you have on these sheets.
  2. C

    A few questions paramount in floor, intelliflo 2, de filter, cracks in waterfall....

    The only gauge I have is at the filter. Is that what you mean? I don't have a gauge anywhere else other than the in floor cleaner. And can't I just actually measure the actual distance? And should I be measuring from the floor drains (I have two near each other on the deep end). I didn't look...
  3. C

    A few questions paramount in floor, intelliflo 2, de filter, cracks in waterfall....

    Hmm I'll have to look closer but it felt pretty solid not hollow in the waterfall. If I have to redo what does something like that usually cost? - - - Updated - - - How do you suggest I calculate the distance and psi you suggest in those sheets? And it looks like the new 011055 is slightly...
  4. C

    A few questions paramount in floor, intelliflo 2, de filter, cracks in waterfall....

    Yeah thanks... sorry wrong model number 011055 is correct for intelliflo 2 vst. I'm not sure that I know all of the variables that are needed for pump tools workbook. I don't know all of the PSI variables and I don't know the pipe length. I do know diameter and could guesstimate the distance...
  5. C

    A few questions paramount in floor, intelliflo 2, de filter, cracks in waterfall....

    Intelliflo GPM estimator v006 - the key is to measure at the same RPM on the pump but I've read that if you run the pump at a lower speed a smaller psi increase can make a bigger difference. And by 30+ I mean by adding and I have had tabs in there for a few weeks. I didn't want to jump it too...
  6. C

    A few questions paramount in floor, intelliflo 2, de filter, cracks in waterfall....

    We had a SWG but I cut it out because it was a Jandy that was older and I believe dead. It was saying it was working but it was 12 years old and the company that had been "servicing" the pool previously was adding tabs even though they had a SWG on a 10k pool - so I feel it wasn't working at...
  7. C

    A few questions paramount in floor, intelliflo 2, de filter, cracks in waterfall....

    I did read that and then promptly forgot! Thanks for the reminder. I'll probably turn down my run time to save on energy significantly. Even when my pump was down the time it took to replace there was no issue because the pool was chlorinated. It stayed clear and we just circulated by brushing...
  8. C

    A few questions paramount in floor, intelliflo 2, de filter, cracks in waterfall....

    Hi everyone. First post. I have been reading up and followed and learned a lot. Just purchased a house with a 10k pebbletec pool and the Jandy Stealth promptly died. We had other issues prior to that which I have resolved but nothing major. I have disassembled the Jandy DEL60 DE filter and...
  9. Photo Jun 25, 9 01 29 AM.jpg

    Photo Jun 25, 9 01 29 AM.jpg

  10. Photo Jun 25, 9 00 49 AM.jpg

    Photo Jun 25, 9 00 49 AM.jpg