Recent content by bdailey

  1. B

    Rough vermiculite floor

    I used a pool float. I just wanted to be sure it wasn't supposed to be slick. Thanks. Sent from my Nexus 6 using Tapatalk
  2. B

    Rough vermiculite floor

    It feels like a rough sand paper. The surface is just not slick like a finished concrete, it is more like open pores. Was going to use a hand sander. A large floor sander would be faster but i think it would remove to much material too fast. Thanks. Sent from my Nexus 6 using Tapatalk
  3. B

    Rough vermiculite floor

    I just finished troweling the vermiculite for for my ig vinyl liner pool. It still has some high spots that need to be knocked down and some low spots to be fill but overall I am happy with the way it turned out. My only concern is that the surface is kind of rough to the touch. Is this...
  4. B

    Light conduit

    So I can use bare copper in the conduit for bonding? Sent from my Nexus 6 using Tapatalk
  5. B

    Light conduit

    Trying to find insulated solid copper #8 awg wire to use as a bonding wire inside the conduit. Having trouble finding it. Anyone know of a good place online. Most of what i find for sold copper is bare. Thanks. Sent from my Nexus 6 using Tapatalk
  6. B

    Light conduit

    Does the bond wire inside the conduit get attached to the lug on the pump with the rest of the bonding or does it get attached to the ground bar inside the transformer. Thanks again. Sent from my Nexus 6 using Tapatalk
  7. B

    Light conduit

    Inside the cord that is attached to the light is a green ground wire, does that count as the bonding wire inside the conduit or do I need to run an additional one. Thanks again. Sent from my Nexus 6 using Tapatalk
  8. B

    Light conduit

    Thanks again for the info. My only concern with using a junction box is it would add a splice to the wire. Could I use a junction box and pass the wire through it without it actually being a "junction". Sent from my Nexus 6 using Tapatalk
  9. B

    Light conduit

    Thanks for the info. I thought the light terminated into the transformer. I was thinking of a junction solely to stop water from entering transformer. Sent from my Nexus 6 using Tapatalk
  10. B

    Light conduit

    Thanks for the reply. No issues with water entering the transformer? Sent from my Nexus 6 using Tapatalk
  11. B

    Light conduit

    Anyone? Sent from my Nexus 6 using Tapatalk
  12. B

    Light conduit

    I am in the middle of a home owner build of an 18x36 IG vinyl liner pool. I will be installing a pentair intellibrite 12v light in a pentair quick niche with an intermatic px300 transformer. My question is about running the conduit between the light niche and the transformer. The transformer...
  13. B

    Pump and filter recommendations

    I am getting ready to begin construction on an 18x36 rectangle vinyl line pool and I am trying to make some equipment decision. Originally I was going to go with the Hayward Ecostar and a Hayward progrid de filter. This is going to be a very basic pool. It will be a little over 19000 gallons...
  14. B

    Diy IG build northeast Florida

    I am in the process of planning a diy IG vinyl liner pool build. I am planning to sub out the dig, the bottom and the electrical. I am looking for any recommendations for excavation, electric, and concrete subs in the Jacksonville Florida area. Any help is greatly appreciated. I have learned...