Recent content by Ausmatt

  1. A

    Which SWG with Aqualink PDA-PS4?

    I can't help with the compare, but I've got a Jandy Aquapure 1400 with the PDA. The PDA lets you set a specific SWG % when you are in Spa Mode and a separate % when you are in Pool Mode. (When I say the PDA, I really mean there's a setting for this ... the control board is setting the SWG when...
  2. A

    Need a salt test?

    Compared to the SWG sensor. Regarding a Taylor test or an electronic tester, I believe the payback period is about 1 year if you test salt and TDS 1-2x/week. (~20 tests per bottle). So for me, it's a good investment and a heck of a lot quicker than a chemical test. But either one is...
  3. A

    Need a salt test?

    I would get an electronic salt tester. I just did so after a recommendation from a pool guy (that did our pool inspection). They run $100 or so from Amazon. I got the ExTech ExStik II. Tests salt, TDS, and temp. I found my SWG was off by several hundred ppm after getting the tester. You can...
  4. A

    Cleaning the SWG cell

    I've been shaping up a new pool (new home) and noticed my FC level won't rise above 2 ppm despite putting SWG at 100% and increasing pump run time by 2 hours (to 8 hours now - 6 hr req for 1 turnover of pool). Water is crystal clear. I'm currently thinking my salt cell needs to be cleaned as I...
  5. A

    Seems to be stable ... please correct my thinking

    After draining ~8000 gallons (with another 2000 gallons still in process of refilling - spillover basin), I'm please to report my CYA has plummeted: Date Salt (ppm) TDS (ppm) FC (ppm) CC (ppm) pH Alkalinity (ppm) Corrected Alk Calcium (ppm) CYA (ppm) Sat Index Notes 6/3/2015 2700 3410 2.5 0...
  6. A

    Seems to be stable ... please correct my thinking

    Thanks. I am using a FAS-DPD kit (Taylor K-2006 and a calibrated electronic salt tester). I tested CYA twice, once the standard way and once with the 50% diluted method in the Taylor manual to make sure the results were this high (and because it only reads up to 100 CYA on kit). The results may...
  7. A

    Seems to be stable ... please correct my thinking

    First, thanks for such a great, informed (scientifically) forum. I'm getting my new home pool in order, and I think I have everything lined up, but want your thoughts on my thoughts -- Pool size: 22k gallons Current chemistry: Salt (ppm) TDS FC (ppm) CC (ppm) pH Alkalinity (ppm) Corrected Alk...
  8. A

    NO FLOW always on

    Wish I would have found this thread before the weekend! I just replaced my flow sensor which solved the No Flow always on issue (and, more importantly, the lack of Cl generation). My previous sensor had a daughterboard and the calibrate button (which I never pushed because I assumed it was a...