      mas985 added the media item 1715621697185.png to Pool Equipment.
      1715621697185.png
    • mas985
      mas985 replied to the thread Intelliflo power consumption.
      Pump VS motors use a VFD (variable frequency drive) which generate a pseudo 3-phase AC waveform using pulse width modulation (PWM) and...
      • 1715621570930.png
      • 1715621697185.png
    • mas985
      mas985 added the media item 1715621570930.png to Pool Equipment.
      1715621570930.png
    • mas985
      mas985 replied to the thread Intelliflo power consumption.
      Reduce RPM and power will go done. Why do you need such a high RPM? Heater, SWG? 1000 RPM is usually going to be the most efficient...
    • mas985
      mas985 replied to the thread low pressure and lots of air.
      Is there a switch on the back of the pump? Take a picture of the pump motor label.
    • mas985
      mas985 replied to the thread low pressure and lots of air.
      7 PSI is very low even for a 3/4 HP pump. Can you post some pictures of the equipment pad? Is that a 2 speed pump running on low speed?
    • mas985
      mas985 replied to the thread low pressure and lots of air.
      That would indicate a suction side clog and/or impeller clog. Things to try: Remove pump basket and see if there is any debris in the...
    • mas985
      mas985 replied to the thread low pressure and lots of air.
      Ok but if the filter pressure is less than normal, then it still indicates either a clogged suction line and/or impeller. Or buy low...
    • mas985
      mas985 replied to the thread low pressure and lots of air.
      Where you vacuuming previous to this happening? Definitely an air leak but it might be due to a clog in either the suction line and/or...
    • mas985
      mas985 replied to the thread Clogged main drain?.
      Given this is in FL and screened in, the PB was probably just relying on only sand and fine debris to be in the pool and if the MD was...
    • mas985
      mas985 replied to the thread Solar Panel Plumbing and Valves.
      A check valve is normally placed between the solar valve and filter where there is no room for it. Also, they stubbed the pipes upward...
    • mas985
      mas985 replied to the thread AQL-PS-8 Remote Emulator App.
      I actually did some time ago but it has changed a bit since then so feel free to share it.
    • mas985
      mas985 reacted to j4ydubs's post in the thread AQL-PS-8 Remote Emulator App with Like Like.
      Thanks for the code. I was just coming here to say I did get it to work. I had to comment out the 2 extra "self._append_data(frame...
    • mas985
      mas985 replied to the thread Clogged main drain?.
      At the pad, there is no pool MD line coming into the pump so most likely it is plumbed through the skimmer. Look into the skimmer...
    • mas985
      mas985 replied to the thread The heck is this thing?.
      It is most likely a pool water bonding point. And yes, it is necessary and VERY important.